Boiler Faults

Worcester Bosch Fault Codes – Complete List With Fixes

October 19, 2026 • admin • 13 min read

Worcester Bosch Fault Codes – Complete List With Fixes

Worcester Bosch is the UK’s best-selling boiler brand — and that means more homeowners searching for Worcester Bosch fault codes than any other make. If your boiler has thrown up a code and locked out, this guide will tell you exactly what it means, whether there’s a quick fix you can do yourself, and when you genuinely need a Gas Safe registered engineer. We cover everything from the very common EA ignition lockout to the more serious 2970 PCB fault.

Before you do anything else: if you can smell gas, do not attempt any reset. Leave the property, call the National Gas Emergency Service on 0800 111 999, and don’t return until it’s been declared safe.

Worcester Bosch Fault Code Quick-Reference Table

The table below covers the most common codes across the Greenstar range (including 2000, 4000, 8000, and CDi models). Some codes appear as letters (E9, EA), some as three-digit numbers (224, 265), and some as four-digit numbers (2970). All are listed here.

Fault CodeMeaningLikely CauseDIY Fix Possible?Next Step
E9Safety thermostat trip / overheat lockoutOverheating due to low flow, air in system, or a failed pumpPartial – check pressure, bleed radiatorsIf it keeps tripping, call a Gas Safe engineer to check pump and heat exchanger
E1Ignition faultNo spark reaching burner – could be ignition lead, electrode, or gas supply issueNo – gas components involvedGas Safe engineer required
EAIgnition lockout (flame not established)Gas supply interrupted, faulty gas valve, dirty flame sensor, or low gas pressureTry one reset; if it repeats, stopGas Safe engineer – gas valve or sensor
224Gas valve faultGas valve not opening or closing correctlyNoGas Safe engineer – valve replacement likely
227Gas pressure too lowLow mains gas pressure, partially closed meter valve, or gas valve faultCheck meter valve is fully openIf meter valve open, call your gas supplier or Gas Safe engineer
228Air pressure fault (no signal)Blocked flue, failed fan, or faulty air pressure switchNoGas Safe engineer – flue or fan inspection
229Air pressure switch stuck openAir pressure switch or connecting hose faultNoGas Safe engineer
265Flue gas temperature too high / flue blockageBlocked flue terminal (leaves, bird nests), or flue pipe joints leakingCheck flue terminal is clear of obstruction from outsideIf terminal clear, Gas Safe engineer for flue inspection
266Flue gas sensor faultFaulty flue gas temperature sensorNoGas Safe engineer – sensor replacement
2970 / 2971PCB (printed circuit board) faultControl board failure – often caused by a power surge or component ageNoGas Safe engineer; PCB replacement is expensive — get a boiler age/cost assessment first
C1Fan speed too lowFan motor failing, wiring fault, or obstructionNoGas Safe engineer – fan replacement
C6Fan speed too highFan running above safe speed – faulty fan or PCB signal issueNoGas Safe engineer

The Most Common Worcester Bosch Fault Codes Explained

EA – Ignition Lockout (the Most Common Code)

The EA code is the Worcester Bosch fault code that gets searched more than any other. It means the boiler tried to light, failed to detect a flame within the safety window, and has locked itself out as a precaution. This is normal safety behaviour — the boiler won’t keep trying to ignite indefinitely.

Common causes include: a temporary dip in gas supply pressure, a dirty or misaligned flame detection electrode, a faulty ignition lead, or a gas valve that isn’t opening fully. On older Greenstar models, a partially blocked condensate trap can occasionally cause this too.

What you can do: Attempt one reset (see reset instructions below). If the boiler fires up and runs normally, job done — it may have been a one-off. If the code comes back within a few hours or the boiler won’t light at all, stop resetting and call a Gas Safe engineer. Repeated ignition attempts without a fix can damage the ignition components further.

E9 – Safety Thermostat / Overheat

The E9 code means the boiler’s safety thermostat has tripped because water temperature got dangerously high. The boiler has shut itself down to prevent damage or a pressure explosion. This is a serious code — don’t keep resetting it and hoping it goes away.

Possible causes: a failing pump that isn’t circulating water fast enough, air trapped in the heat exchanger, sludge buildup restricting flow, or a faulty safety thermostat itself. If your boiler keeps cutting out, an overheating issue is one of the most frequent culprits.

What you can do: Check your system pressure (it should be between 1 and 1.5 bar when cold). Bleed any radiators that feel cold at the top — trapped air reduces circulation. If pressure and bleeding don’t resolve it, this needs a Gas Safe engineer to check the pump and heat exchanger for sludge.

228 and 229 – Air Pressure Faults

These two codes relate to the air pressure switch — a safety device that checks the fan is running and the flue is clear before allowing ignition. Code 228 means the switch isn’t seeing any pressure signal at all (fan not running, or blocked flue), while 229 means the switch is stuck open when it shouldn’t be.

The most DIY-friendly check here is to look at your external flue terminal (the white plastic pipe sticking out of an external wall or through your roof). If it’s covered in debris, a bird’s nest, or ice in winter, clear it. But don’t probe the flue terminal with anything sharp — you could damage the pipe. If the terminal looks clear, this is an engineer job.

2970 / 2971 – PCB Fault

A PCB fault on any boiler is the diagnosis you don’t want to hear, because PCBs are expensive. On Worcester Bosch boilers, codes 2970 and 2971 indicate the main printed circuit board has developed a fault. Replacement parts typically cost £300–£500 plus labour, bringing the total repair to £500–£800 or more.

If your Worcester Bosch is more than 10 years old and showing a PCB fault, it’s worth getting a proper assessment before spending on a repair. Boiler replacement costs in 2026 have come down significantly, and a new Worcester Bosch Greenstar 4000 with a 12-year warranty may be better value than repairing an ageing unit.


How to Reset a Worcester Bosch Boiler

The reset procedure is the same across most modern Worcester Bosch Greenstar models:

On the older Worcester Bosch CDi range, the reset button is a physical push-button on the front panel. On newer Greenstar 4000 and 8000 models with a digital display, the reset function may be accessed through the menu — check your manual or the Worcester Bosch support site for your specific model.


DIY Fixes vs When You Must Call a Gas Safe Engineer

UK law is clear on this: only a Gas Safe registered engineer is legally permitted to work on gas appliances, including boilers. This isn’t bureaucratic box-ticking — a gas leak or incorrect repair can kill. Always ask to see an engineer’s Gas Safe ID card before any work begins.

What you can safely do yourself:

Everything else — gas valves, ignition components, heat exchangers, fans, sensors, PCBs — requires a qualified engineer. If you’re unsure whether your boiler is working correctly after a reset, use our boiler diagnosis guide to assess the situation before calling out.


Worcester Bosch Boiler Warranty and Repair Costs

Worcester Bosch offers one of the best warranty packages in the UK. Depending on the model and whether it was installed by a Worcester Bosch Accredited Installer, you may be entitled to:

Importantly, having any gas component repaired by an unregistered person will void your warranty immediately and permanently. Even if the repair looks successful, Worcester Bosch will not honour any subsequent claim.

If your boiler is out of warranty and facing a major repair, Which? has a useful repair-vs-replace calculator that factors in boiler age, energy efficiency, and repair cost. As a rough rule: if the repair costs more than half the price of a new boiler of equivalent spec, replace it.


Reducing Future Fault Codes

Many Worcester Bosch fault codes are preventable with proper maintenance. An annual boiler service by a Gas Safe engineer typically costs £60–£100 and catches minor issues before they become fault codes. The Energy Saving Trust notes that a well-maintained boiler runs more efficiently, directly reducing your bills under the Ofgem price cap structure.

Additionally, fitting a magnetic system filter (such as a Magnaclean or Fernox TF1) will catch the iron oxide sludge that circulates in older systems — the same sludge that causes E9 overheats and pump failures. If your Worcester Bosch has thrown multiple fault codes over recent winters, a power flush combined with inhibitor dosing is worth considering before the next cold snap.

If you’re considering upgrading, see our guide to the best combi boilers available in the UK in 2026 — Worcester Bosch features prominently, but there are strong alternatives at lower price points too.