“Central Heating Not Working UK: Full Diagnosis Guide”
If your central heating has stopped working, the fault is usually one of five things: boiler pressure, thermostat settings, stuck…
When your central heating stops working, the cause is almost always one of a handful of common faults. Some you can fix in five minutes yourself. Others need a Gas Safe engineer. This guide walks you through a systematic diagnosis — from the simplest checks to the more serious faults — so you can either resolve the problem yourself or describe it accurately when you call a professional.
This article contains affiliate links. If you buy through them, we may earn a small commission at no extra cost to you. This doesn’t affect our editorial independence — we only recommend products we’d genuinely suggest to a friend.

Before calling an engineer, run through these quick checks. They resolve a surprising number of calls:
Check that your thermostat is set above the current room temperature. A smart thermostat in “away” or “eco” mode will suppress heating even if you think you’ve turned it on. Check the app if you have a Hive, Tado or Nest system. If you have a manual thermostat, turn it up to 25°C and see if the boiler fires.
Many heating failures are simply the programmer being set to the wrong time or switched to “off” accidentally. Check the boiler programmer or smart thermostat schedule. If the programmer has lost its settings (after a power cut, for example), it will often default to “off” and need reprogramming.
Look at your boiler’s display panel. If it shows a fault code (such as E1, F28, EA338, or similar), that code identifies the specific fault. Look up your boiler model’s fault codes — we have guides for Worcester Bosch, Vaillant, Ideal, and Baxi fault codes. Try pressing the reset button (usually a flame symbol with a line through it) once — a one-off lockout can clear this way.
Check that other gas appliances (cooker, gas fire) are working. If nothing gas-powered works, contact your gas supplier — there may be a supply issue in your area. Check National Grid’s gas emergency line (0800 111 999) if you suspect a wider supply problem.
Low boiler pressure is the single most common reason a combi or system boiler stops heating. The correct pressure for most boilers when cold is 1.0–1.5 bar. Look at the pressure gauge on the front of the boiler (or in the display menu on digital models).
To repressurise, locate the filling loop (a silver braided hose usually under the boiler) and open the two valves slowly until the pressure reaches 1.2–1.5 bar, then close both valves and press reset. Full instructions are in our low boiler pressure guide. If the pressure drops again within days, there is a leak in the system that needs professional attention — do not keep repressurising without finding the cause.
If your hot water works but the radiators don’t heat up, the most likely causes are:
See our dedicated guide to no hot water when heating works for a full diagnosis. On a combi boiler, common causes include a failed diverter valve or low hot water flow rate. On a system boiler, check the hot water cylinder thermostat and that the immersion heater or zone valve is functioning.
If some radiators heat up but others don’t:
If the boiler fires up (you can hear it and it’s warm) but no heat reaches the radiators, the most likely cause is a failed circulating pump. The pump circulates hot water around the system — if it’s seized or failed, heat cannot reach the radiators. A pump replacement typically costs £150–£350 fitted. This is a job for a Gas Safe engineer.
A boiler that ignites and then locks out within a few seconds typically has one of these faults: a faulty flame sensor (also called an ionisation probe), a faulty gas valve, or inadequate gas pressure. All three require an engineer. Try pressing reset once to see if the lockout clears — if the boiler locks out again after the same short cycle, there is a component fault that needs investigation.

| Symptom | Most likely cause | DIY fix possible? | Typical repair cost |
|---|---|---|---|
| No heating or hot water, low pressure | Pressure loss | Yes — repressurise | Free |
| No heating but hot water works | Diverter valve / zone valve | No | £150–£350 |
| Boiler fires then locks out | Flame sensor / gas valve | No | £100–£300 |
| All radiators cold, boiler running | Pump failure | No | £150–£350 |
| Some radiators cold at top | Trapped air | Yes — bleed radiators | Free |
| Some radiators cold overall | Sludge / TRV fault | Partial — try TRVs | £80–£600+ |
| Boiler making gurgling noise | Air or sludge in system | Partial | Free–£400 |
| Boiler pressure keeps dropping | System leak | No | £100–£500+ |
Call a Gas Safe engineer immediately if:
For non-emergency faults, verify any engineer you call is on the Gas Safe Register before they begin work. Only Gas Safe engineers are legally permitted to work on gas boilers and central heating in the UK. The Energy Saving Trust’s central heating guide provides independent advice on heating controls, boiler maintenance, and energy-saving settings. For a comparison of repair costs and boiler cover options, see our emergency boiler repair cost guide and best boiler cover comparison.
If your central heating has stopped working, the fault is usually one of five things: boiler pressure, thermostat settings, stuck…
A gurgling boiler is almost always caused by one of four things: air in the system, low water pressure, a…
Your Worcester Bosch boiler is showing a fault code and you need answers fast. This guide covers every common code…