If your boiler is not working, don’t panic and don’t immediately call an engineer — the most common causes are things you can diagnose yourself in under ten minutes, and several have free fixes. This step-by-step guide walks through every likely cause in order of probability, tells you exactly what to look for, and is honest about where the DIY stops and a Gas Safe registered engineer needs to take over.
Start at the boiler itself. Look at the display panel or indicator lights.
No display at all? Check these before anything else:
If resetting the circuit breaker brings the boiler back but it trips again quickly, stop — there’s an electrical fault that needs an engineer.
Display is on but boiler isn’t firing? Continue to Step 2.
Low pressure is one of the most common reasons a boiler won’t fire. Almost all modern combi and system boilers have a pressure gauge — either a clock-face dial or a digital reading on the display. The needle or number should sit between 1 and 1.5 bar when the system is cold.
Reading below 0.5 bar? The boiler has locked out on low pressure. You need to repressurise it via the filling loop — a braided hose that connects the mains water supply to the heating circuit, usually under the boiler. See our full guide to fixing low boiler pressure for step-by-step instructions.
Pressure normal (1–1.5 bar)? Carry on to Step 3.
In winter — particularly during any cold snap below freezing — a frozen condensate pipe is the single most common reason a boiler stops working in the UK. The condensate pipe carries waste water (acidic condensate) from the boiler to an outside drain. When it freezes, the boiler detects a blockage, displays a fault code, and shuts down.
How to identify it:
The fix (free, DIY, takes 5 minutes):
The Energy Saving Trust recommends pipe lagging as a routine winter maintenance task — it takes minutes and could save you a £100+ call-out fee.
Before assuming anything is broken, rule out a settings issue:
Modern boilers display alphanumeric fault codes when something goes wrong — these are your single most useful diagnostic tool. If you see a code on the display, search for “your boiler make + model + fault code” to get the exact meaning, or check your manual.
Here are the most common codes and what they mean:
| Brand | Common Code | Meaning | Likely Action |
|---|---|---|---|
| Worcester Bosch | EA 338 | Frozen condensate | DIY thaw (see Step 3) |
| Ideal | F1 | No ignition / gas fault | Engineer needed |
| Vaillant | F28 | Ignition failure | Engineer needed |
| Vaillant | F29 | Flame loss / gas supply | Check gas, then engineer |
| Baxi | E168 | Low water pressure | Repressurise (see Step 2) |
| Glow-worm | F9 | Condensate blocked | DIY thaw (see Step 3) |
If the boiler has power and pressure, the fault code points to ignition failure, or you can hear the boiler trying to light but failing, check your gas supply:
Never attempt to work on gas pipework or the boiler’s gas valve yourself. This is a legal requirement in the UK — all gas work must be carried out by a Gas Safe registered engineer.
If your boiler is more than 15 years old, it may have a standing pilot light rather than electronic ignition. A pilot light that has gone out is a common fault on older appliances.
You can relight a pilot light yourself — the procedure is written on the inside of the boiler casing or in the manual. However, if the pilot won’t stay lit after following the instructions, or keeps going out repeatedly, the thermocouple (a safety device) is likely failing. This is a £50–£100 engineer job, but it’s worth asking whether a boiler this age is worth repairing. See our guide to boiler replacement costs in 2026 for context.
Call an engineer if any of the following apply after working through the steps above:
An annual boiler service (typically £80–£120) is the best way to prevent unplanned breakdowns. Read our breakdown of boiler service costs in the UK to know what you should be paying.
| Symptom | Most Likely Cause | DIY or Engineer? |
|---|---|---|
| No display at all | Power / fuse / spur | DIY check first |
| Display on, won’t fire, winter | Frozen condensate pipe | DIY (thaw pipe) |
| Low pressure reading | Needs repressurising | DIY |
| Fault code: ignition failure | Ignition electrode / gas valve | Engineer |
| Thermostat or timer issue | Settings error | DIY check first |
| Gas hob also not working | Gas supply interrupted | Call 0800 111 999 |
| Repeated lockouts | Component failure | Engineer |