“Central Heating Not Working: Full Diagnosis Guide”
When your central heating stops working in the UK, the cause is usually one of a small number of common…
Central heating failing in the UK — particularly in autumn or winter — is one of the most stressful household problems you can face. The good news is that the fault is almost always one of a small number of causes, and many of them can be identified and sometimes fixed without calling an engineer. This guide walks you through a structured diagnosis in the order most likely to find your fault quickly. Work through each step before moving to the next.
This article contains affiliate links. If you buy through them, we may earn a small commission at no extra cost to you. This doesn’t affect our editorial independence — we only recommend products we’d genuinely suggest to a friend.

Start at the boiler itself. Many central heating failures are actually boiler faults — the boiler has locked out and needs to be reset, or a simple issue like low pressure has stopped it firing.
Most combi and system boilers have a pressure gauge visible on the front. It should read between 1 and 1.5 bar when the system is cold (and up to 2 bar when hot). If it reads below 0.8 bar, the system pressure is too low and the boiler will not fire. Repressurise using the filling loop — usually a silver braided hose under the boiler connecting to the mains. Open both valves slowly until pressure reaches 1.2 bar, then close both. See our full guide to low boiler pressure for step-by-step instructions.
If your boiler has a digital display showing a fault code, that code tells you exactly what it has detected wrong. Common codes by brand:
| Brand | Common No-Heating Code | Likely Cause |
|---|---|---|
| Worcester Bosch | EA 338 / EA 227 | Ignition failure / condensate blockage |
| Vaillant | F.28 / F.29 | Gas supply / ignition fault |
| Ideal | L2 / F1 | Overheat / ignition lockout |
| Baxi | E133 / E168 | Ignition failure / gas valve fault |
| Alpha | E10 / E28 | No flame / overheat |
Look up your specific code in your boiler manual or search for “[brand] fault code [code]”. A Gas Safe engineer is needed to diagnose and fix most fault codes — do not attempt to override safety lockouts yourself.
If the boiler has locked out (most display a flashing light or “F” code), press and hold the reset button for 3–5 seconds as described in your manual. If it fires up and runs normally, the lockout may have been a one-off event (e.g., a brief drop in gas pressure). If it locks out again within a few cycles, call a Gas Safe engineer — repeated lockouts indicate an underlying fault.
If the boiler appears to be running normally but no heat is reaching the radiators, the fault may be with the room thermostat or its settings — particularly if you have recently changed from summer to winter mode.
If the boiler is firing and some radiators are warm but others are not, the fault is likely in the distribution system rather than the boiler itself.
Air trapped in a radiator prevents hot water from filling it. A cold top with a warm bottom is the classic sign. Bleed each affected radiator using a radiator key — turn it anti-clockwise until you hear air escaping, wait until water begins to drip out steadily, then close it. Check boiler pressure afterwards and top up if it has dropped below 1 bar. See our detailed how to bleed a radiator guide.
TRVs (the valves on the side of most radiators) can stick in the closed position — particularly in summer when they have not been used for months. If a radiator is completely cold and bleeding produces no air, the TRV pin may be stuck. You can often free it by removing the TRV head and pressing the pin in and out several times with your thumb. If it does not budge, replacement TRV heads cost £10–£25 and are a straightforward DIY job on most radiators.
The circulation pump pushes hot water from the boiler around the radiators and back. If it fails, the boiler may fire but no heat will circulate. Signs of a pump fault:
Circulation pump replacement typically costs £200–£400 including parts and labour. This is work for a Gas Safe registered engineer. Do not attempt to diagnose the pump further yourself if it involves electrical connections near gas pipework.
System boilers and heat-only boilers (with a hot water cylinder) use motorised zone valves to direct water to the heating circuit or the hot water circuit separately. If a zone valve fails or sticks in the wrong position, you may get hot water but no heating, or heating but no hot water. Zone valve replacement costs £150–£300 including labour and is a job for a Gas Safe engineer.
Most central heating call-outs in the UK that require an engineer turn out to be caused by one of three issues: low boiler pressure, a stuck TRV, or air in the system — all of which can be checked and often resolved by the homeowner before calling for help.

Call a Gas Safe registered engineer immediately if:
For non-emergency faults, an emergency boiler repair call-out typically costs £80–£150 just to attend, plus parts. If cost is a concern, check whether you have boiler cover or a home emergency policy that covers the call-out.
This guide provides general diagnostic information for UK homeowners. All gas work must be carried out by a Gas Safe registered engineer. If in doubt, call a professional rather than attempting repairs yourself.