Vaillant Fault Codes – F75, F22, F28, F29 Explained

October 17, 2026 • admin • 13 min read

Vaillant Fault Codes – F75, F22, F28, F29 Explained

Vaillant is the second most popular boiler brand in the UK, and the ecoTEC range is in millions of British homes. When a Vaillant fault code appears on your display, it can look alarming — but many of these codes have straightforward causes and some, like F22, you can fix yourself in five minutes. This guide explains every common Vaillant fault code, tells you clearly which ones are DIY resets and which ones require a Gas Safe registered engineer, and covers the most searched codes — F75, F22, F28, and F29 — in detail.

As always: if you can smell gas, do not reset or attempt any repair. Leave the property and call the National Gas Emergency Service on 0800 111 999.

Vaillant Fault Codes – Full Quick-Reference Table

Fault CodeMeaningLikely CauseDIY or Engineer?Next Step
F22Low water pressureSystem pressure dropped below minimum (usually below 0.5 bar)DIY — repressuriseTop up pressure via filling loop to 1–1.5 bar, then reset
F75Pump or pressure sensor faultPump not running when it should, or pressure sensor unable to detect pump activityEngineerGas Safe engineer – pump or pressure sensor replacement
F28Ignition failureNo spark or failed gas ignition after 3 attemptsTry one reset; then engineerGas Safe engineer – ignition electrode, lead, or gas valve
F29Flame failureFlame established then lost during operation – gas supply issue, faulty flame sensor, or gas valveTry one reset; then engineerGas Safe engineer if fault repeats
F61Gas valve fault (control error)Gas valve not responding to PCB signal correctlyEngineerGas Safe engineer – gas valve replacement
F62Gas valve shut-off faultGas valve failing to close properly – a safety-critical faultEngineer – urgentDo not reset repeatedly. Gas Safe engineer immediately
F63EEPROM fault (memory chip)Control board memory fault – settings data corruptedEngineerGas Safe engineer – PCB may need replacement
F64Flow/return heat exchanger sensor faultNTC sensor measuring heat exchanger temperature has failedEngineerGas Safe engineer – sensor replacement
F65Flue gas temperature sensor faultFlue thermistor failure or wiring issueEngineerGas Safe engineer
F72Pressure sensor offset errorPressure sensor giving incorrect readings – usually sensor faultEngineerGas Safe engineer – pressure sensor replacement
F73Pressure sensor signal stuck lowPressure sensor permanently reading below minimum – sensor stuck or faultyEngineerGas Safe engineer – often same repair as F75

F22 – Low Water Pressure (Fix This Yourself)

F22 is the Vaillant fault code that homeowners are most relieved to see — because it’s usually a straightforward DIY fix. It means your system water pressure has dropped below the minimum threshold (typically 0.5 bar), and the boiler has shut down as a safety measure.

System pressure drops gradually over time through normal operation. Small amounts of water are lost through the pressure relief valve, through microbubbles venting from radiators, and at connection points. Annual top-ups are normal. If you’re topping up more than twice a year, there may be a slow leak somewhere in the system that needs finding.

How to Fix Vaillant F22

If the pressure drops again within days or weeks, you have a leak. Our boiler diagnosis guide covers how to trace a pressure loss.


F75 – The Most Notorious Vaillant Fault Code

F75 is the Vaillant fault code that generates more online discussion than any other — and with good reason. It’s one of the most common codes on ecoTEC boilers, particularly on units over 5 years old, and it points to a fault with either the pump or the pressure sensor (or both).

Here’s what’s happening: when the Vaillant ecoTEC starts up, it activates the pump and then checks via a pressure sensor that the pump is actually moving water. If the pressure sensor doesn’t detect the expected pressure change — either because the pump has failed, because the sensor itself is faulty, or because the sensor is clogged with system sludge — it throws F75 and locks out.

Why F75 is So Common on Vaillant ecoTEC Boilers

The pressure sensor on older ecoTEC models (particularly pre-2015 units) is known to be prone to clogging with magnetite sludge. This is the black iron oxide that circulates in central heating systems and gradually accumulates in low-flow areas — including the pressure sensor port. When the sensor port is blocked, it cannot detect pressure changes correctly even if the pump is working fine.

A Gas Safe engineer will often try cleaning the sensor port before condemning the sensor or pump. Replacement sensors cost around £30–£80 in parts. Pump replacement is more expensive — typically £150–£300 in parts plus labour.

If F75 appears on an older system without a magnetic filter, fitting one after the repair is strongly recommended to prevent a recurrence. The Energy Saving Trust notes that system maintenance including inhibitor dosing extends boiler life significantly.


F28 – Ignition Failure

F28 means the Vaillant boiler made three attempts to ignite and failed on all three. It then locked out. This is standard safety behaviour across all modern boilers — attempting to ignite indefinitely with no flame would be dangerous.

Common causes of F28 include: a temporary interruption in gas supply (check that other gas appliances in your home are working), a faulty ignition electrode that isn’t producing a reliable spark, a damaged ignition lead, or a gas valve that isn’t opening correctly. In cold weather, a frozen condensate pipe can also indirectly trigger F28 by causing the boiler to lock out.

Attempt one reset. If the boiler fires and runs normally, monitor it over the following hours. If F28 returns, it needs a Gas Safe engineer — don’t keep resetting, as you may damage components or risk a gas buildup.


F29 – Flame Failure During Operation

Where F28 is a failure to ignite, F29 means the boiler successfully lit but the flame then went out unexpectedly during operation. This can happen because of gas supply fluctuations, a fault with the flame detection electrode (which is often the same component as the ignition electrode on Vaillant ecoTEC models), or a gas valve that’s not holding the gas flow stable.

F29 is sometimes seen in winter when external gas demand is high and mains gas pressure drops temporarily. If it happens once and then behaves normally after a reset, it may have been a one-off. If it recurs, a Gas Safe engineer needs to check gas pressure at the boiler and inspect the flame sensor.

If your boiler keeps cutting out repeatedly, F29 is one of the common fault codes behind that behaviour — along with F22 and F75.


F61 and F62 – Gas Valve Faults (Do Not Ignore)

F61 and F62 are both gas valve faults, but they’re meaningfully different. F61 indicates a control error — the PCB sent a signal to the gas valve and got an unexpected response, suggesting the valve isn’t functioning correctly. F62 is more serious: it means the gas valve failed to shut off when it should have. This is a safety-critical fault.

Neither of these codes should be repeatedly reset. A gas valve that isn’t closing properly represents a genuine safety risk. Call a Gas Safe engineer promptly. Replacement gas valves for the Vaillant ecoTEC typically cost £100–£200 in parts plus labour, making the total repair £250–£450.

Always verify your engineer is Gas Safe registered by checking the Gas Safe Register’s Find an Engineer tool before work begins.


How to Reset a Vaillant Boiler

The reset procedure varies slightly between Vaillant ecoTEC models, but the most common method on the ecoTEC Pro, Plus, and Exclusive ranges is:

If you have a Vaillant ecoTEC with a rotary dial rather than buttons, rotate the dial to the reset position (marked with the reset symbol) and hold. If in doubt, refer to your specific model’s manual on the Vaillant UK support pages.


Vaillant Fault Codes: DIY vs Engineer Summary

To be clear about what requires a professional:

If your Vaillant boiler is reaching the end of its life or facing an expensive repair, it’s worth comparing against replacement costs. Which? has a repair-versus-replace guide that factors in boiler age and current energy prices. See also our guide to boiler replacement costs in 2026 and our best combi boilers roundup if you’re considering a new installation.

#F75 #Fault Codes #vaillant