“Central Heating Not Working: Full Diagnosis Guide”
When your central heating stops working in the UK, the cause is usually one of a small number of common…
Baxi is one of the UK’s best-known mid-range boiler brands, with millions of units installed across the country under both the Baxi and Potterton names. If your Baxi boiler is displaying a fault code, this guide will tell you exactly what it means, whether you can fix it yourself, and when you need a Gas Safe registered engineer. The most commonly searched Baxi fault codes — E119 (low pressure), E1 (ignition failure), and E2 (overheat) — are all covered here in detail, along with the full code list for Baxi 800, Baxi 600, Baxi Duo-tec, and related models.
One important note before you start: Baxi and Potterton are owned by the same parent company (BDR Thermea) and share the same boiler platform. If you have a Potterton Performa, Gold, or Titanium, the fault codes and procedures in this guide apply equally to your boiler.
Gas safety first: if you can smell gas, leave the building immediately and call the National Gas Emergency Service on 0800 111 999. Do not attempt any reset or repair.
| Fault Code | Display | Meaning | Likely Cause | DIY or Engineer? |
|---|---|---|---|---|
| E1 | E1 / Flame symbol flashing | Ignition failure / lockout | No spark or flame not established — gas supply issue, faulty electrode or lead, dirty flame sensor | Try one reset; engineer if it repeats |
| E2 | E2 | Safety thermostat tripped / overheat | Overheating due to pump failure, low flow rate, blocked heat exchanger, or air in system | Check pressure and bleed rads; engineer if persists |
| E119 | E119 | Low water pressure | System pressure below minimum — normal gradual loss, or a leak | DIY — repressurise the system |
| E125 | E125 | Flame failure (flame lost during operation) | Gas supply interruption, faulty flame detection electrode, or gas valve fault | Try one reset; Gas Safe engineer if repeats |
| E160 | E160 | Fan fault | Fan not running at correct speed or not running at all — motor failure or wiring fault | Engineer |
| E168 | E168 | PCB / control board fault | Control board failure — often following a power surge or component age | Engineer — assess repair vs replace |
| E133 | E133 | Gas supply fault / gas valve issue | No gas reaching the boiler, meter valve issue, or gas valve failure | Check meter valve; engineer if valve open |
| E28 | E28 | Flue blocked or wind interference | Blocked flue terminal, high winds causing backdraught, or bird obstruction | Check external terminal; engineer if clear |
| E20 | E20 | NTC flow sensor fault | Water temperature sensor (thermistor) failure or wiring fault | Engineer |
| E110 | E110 | Overtemperature / safety cutout | Water temperature exceeded safe limit — similar cause to E2 | Check pressure; engineer if persists |
| E131 | E131 | Gas valve activation fault | Gas valve not responding correctly to PCB control signal | Engineer — gas valve or PCB |
| E193 | E193 | Communication fault (on system boilers) | Communication error between boiler and external controls or DHW sensor | Engineer — wiring or controls check |
The E119 fault code is the single most common reason a Baxi boiler stops working, and the good news is it’s usually something you can fix yourself in under 10 minutes. E119 means the system water pressure has fallen below the safe operating minimum — on most Baxi models, that’s around 0.5 bar.
Central heating systems lose small amounts of water over time through normal use. Micro-bubbles vent from radiators, tiny amounts escape through the pressure relief valve, and fittings very gradually weep. This is normal. A top-up once or twice a year is expected. If you’re topping up every few weeks, there is a leak somewhere in the system that needs proper investigation.
If the pressure gauge won’t rise, the filling loop valve may be seized from disuse — try a gentle quarter-turn anticlockwise with a flat-headed screwdriver. If pressure rises but immediately drops back again, you have an active leak. Use our boiler diagnosis guide to locate it, or call a plumber.
E1 on a Baxi boiler means the ignition sequence failed — the boiler tried to light and couldn’t establish a stable flame within the permitted number of attempts. It has locked out to prevent repeated ignition failures from allowing gas to accumulate.
Start by checking whether other gas appliances in your home (gas hob, gas fire) are working. If they’re not, you have a gas supply issue — call your gas supplier or National Grid Gas. If other appliances are fine, the problem is internal: a worn ignition electrode, a damaged ignition lead, a dirty or misaligned flame detection sensor, or a faulty gas valve.
Attempt one reset. If the boiler fires and runs normally, monitor it. If E1 returns, stop resetting — you need a Gas Safe engineer to inspect the ignition system. Baxi ignition electrodes are a relatively inexpensive repair (typically £100–£200 all-in), so this is worth fixing if the boiler is otherwise in good condition. If your boiler keeps cutting out, E1 is one of the common fault codes to investigate first.
E2 means the boiler’s built-in safety thermostat has detected that water temperature reached a dangerously high level and has tripped. The boiler will not restart while the overheat condition exists. This is a serious fault — do not keep resetting it without understanding the cause.
The most common causes of E2 are: a failing circulation pump that isn’t moving water around the system fast enough, severe sludge buildup in the heat exchanger restricting water flow, an airlocked system (check if radiators are cold at the top and need bleeding), or occasionally a faulty safety thermostat that’s tripping at the wrong temperature.
Check your pressure gauge — it should read 1–1.5 bar. Bleed your radiators. If everything looks normal and E2 continues to appear, this requires a Gas Safe engineer to assess pump operation and heat exchanger condition. Sludge-related issues on older systems often benefit from a power flush.
E28 is a flue-related fault that’s more common in exposed locations or during severe weather. It means the boiler’s air pressure monitoring system has detected a problem with the flue — either something is blocking the terminal, or wind is causing backdraught that upsets the combustion air supply.
Go outside and look at your flue terminal (the pipe exiting through an external wall or roof). Check for obvious blockages: debris, a bird’s nest, ice buildup in winter, or damage to the terminal itself. Clear any external obstruction carefully — but don’t insert anything into the flue pipe itself. If the terminal looks clear, the fault may be inside the flue run or with the air pressure switch, both of which need a Gas Safe engineer.
In exposed or coastal locations, a wind deflector fitted around the flue terminal can reduce the frequency of E28 faults in high winds. Ask your engineer about this during the service visit.
E168 is the Baxi fault code nobody wants to see. It indicates a control board (PCB) failure. PCBs are the most expensive component in a boiler to replace — typically £300–£600 in parts, plus £100–£200 in labour, making a total repair cost of £400–£800 or more.
Before authorising a PCB replacement, always get a professional assessment of your boiler’s overall condition and age. On a Baxi boiler under 8 years old in otherwise good condition, a PCB replacement may be worthwhile. On a 15-year-old boiler that’s already had repairs, the money is often better invested in a new boiler. See our guide to boiler replacement costs in 2026 for a realistic comparison.
The reset procedure varies slightly depending on which Baxi model you have. Here’s a breakdown for the main ranges:
If you’ve reset twice and the fault code keeps returning, stop resetting and arrange an engineer visit. Repeated resets without diagnosis can mask deteriorating components.
This is worth emphasising because many homeowners don’t realise it: Baxi and Potterton are the same boiler under different badges. Both brands are owned by BDR Thermea and share the same engineering platform. A Potterton Performa 24 is mechanically identical to its Baxi equivalent, with the same fault codes, the same reset procedures, and the same spare parts.
If you’ve found this guide and you have a Potterton — every piece of information here applies to you too.
Baxi boilers have a reasonable reputation for reliability, and the 800 series comes with a 10-year warranty when installed and registered correctly. However, older Baxi models — particularly the Duo-tec and some early Platinum units — can become expensive to maintain as they age.
The general rule of thumb: if a repair costs more than a third of the price of a comparable new boiler, and the boiler is over 10 years old, get replacement quotes. Which? has a useful repair-versus-replace calculator that takes energy efficiency into account — important given Ofgem price cap levels.
Annual boiler servicing is the single best thing you can do to keep fault codes at bay. The Energy Saving Trust confirms that regular servicing maintains efficiency, extends boiler lifespan, and keeps your warranty valid. If you’re thinking about a new installation, see our guide to the best combi boilers in 2026.
When your central heating stops working in the UK, the cause is usually one of a small number of common…
If your central heating has stopped working, the fault is usually one of five things: boiler pressure, thermostat settings, stuck…
A gurgling boiler is almost always caused by one of four things: air in the system, low water pressure, a…