“Megaflo vs Combi Boiler UK: Which Hot Water System Is Better for Your Home?”
A Megaflo unvented cylinder stores hot water at mains pressure and suits large households with two or more bathrooms. A…
Boiler pressure dropping overnight — or any time the heating isn’t running — is a different problem from the garden-variety low pressure that happens after bleeding radiators. If you’re regularly waking up to a pressure gauge below 1 bar without having touched the system, something is actively losing water or failing to hold the system pressure steady. This article explains the three most likely causes, how to identify each one, and what you can realistically fix yourself versus what needs a Gas Safe engineer.
If you’ve simply bled your radiators recently and the pressure dropped as a result, that’s normal — you just need to top it back up. See our guide on how to fix low boiler pressure for repressurising instructions. This article is specifically for pressure that drops on its own, repeatedly, with no obvious explanation.
A sealed central heating system is exactly that — sealed. Once filled to the correct pressure, it should stay at roughly 1–1.5 bar indefinitely when cold, rising to around 2–2.5 bar when hot. If the pressure is falling without you doing anything, water is escaping somewhere — either out of the system entirely (a leak) or being absorbed into a component that’s no longer doing its job (a failed expansion vessel).
A small pressure drop of 0.1–0.2 bar between heating cycles can be normal, particularly on older systems. But if you’re adding water more than once a month, or the pressure is consistently below 0.5 bar by morning, you have one of the three problems below.
This is the most common cause of pressure that drops steadily over days or weeks. The frustrating thing is that heating system leaks are often invisible — the water may be escaping from a joint or valve at a rate slow enough to evaporate before you see it, or the pipework may run under floorboards or through walls.
DIY or engineer? Tightening a loose compression fitting or replacing a radiator valve are tasks a competent DIYer can handle. But if the leak is in buried pipework or soldered joints, you need a plumber or heating engineer. Don’t ignore a leak — even a slow one can cause structural damage over time and will keep driving your pressure down.
The expansion vessel is a small pressurised tank — usually fitted inside the boiler casing or on the pipework nearby — that absorbs the increase in water volume as the system heats up. Inside it is a rubber diaphragm separating a sealed gas (nitrogen) charge from the system water.
When the diaphragm perishes or the nitrogen charge is lost, the vessel can no longer absorb the expansion. The result is a boiler that reaches dangerously high pressure when hot (causing the pressure relief valve to discharge water — see Cause 3 below) and then drops to low pressure when it cools down. This is the classic pattern: pressure is normal or high when the heating is running, then drops overnight as the system cools.
DIY or engineer? Re-pressurising an expansion vessel (if the diaphragm is still intact but the charge has been lost) is a job some experienced DIYers tackle with a tyre pump, but it requires the system to be depressurised first. A failed diaphragm means the vessel needs replacing — this is a £150–£300 job for an engineer including parts, and it’s well worth doing rather than repeatedly topping up pressure.
The pressure relief valve (PRV) is a safety device that opens automatically if the system pressure exceeds a set limit (usually 3 bar) to prevent damage. Once opened, PRVs don’t always reseat perfectly — they can develop a small, permanent weep that slowly drains water from the system.
DIY or engineer? Replacing a PRV is a relatively straightforward plumbing job, but it requires isolating and draining the heating circuit first. The valve itself costs £20–£40; engineer labour adds £80–£150. Critically, if your PRV is discharging because the system pressure is genuinely running too high, replacing the valve without fixing the root cause (usually the expansion vessel) will just cause the new valve to fail too.
| What You Observe | Most Likely Cause | Typical Fix Cost |
|---|---|---|
| Slow, steady drop over days or weeks | Hidden leak in pipework or valves | £100–£300 depending on location |
| Normal when hot, drops sharply when cool | Failed expansion vessel | £150–£300 (vessel replacement) |
| Water dripping from external pipe near boiler | Weeping pressure relief valve | £100–£250 (valve + labour) |
| Pressure fine after top-up, drops within days | Any of the above; seek engineer diagnosis | Varies |
The worst thing you can do with boiler pressure dropping overnight is keep topping up the system via the filling loop without investigating the cause. Every time you add water to a leaking or faulty system, you’re also adding fresh oxygen and minerals — this accelerates corrosion inside the radiators and pipework, and can cause sludge build-up that leads to more expensive repairs down the line.
If you’re topping up the system more than once every six weeks, call a heating engineer for a proper diagnosis. A one-hour call-out to find and fix the cause is far cheaper than years of sludge damage or a premature boiler replacement. When you do book an engineer, check they’re registered at Gas Safe Register.
A failing expansion vessel left unrepaired typically leads to repeated PRV discharges. A PRV that weeps regularly can deposit scale and debris on the valve seat, eventually preventing it from closing at all — at which point the valve needs replacing urgently to keep the system safe. Meanwhile, the constant water top-ups are progressively corroding your heating system from the inside.
For context on the bigger picture: if your boiler is over 12 years old and you’re facing a £200–£300 expansion vessel repair on top of other niggles, it may be time to weigh repair against replacement. Our guide to boiler replacement costs in 2026 lays out what a new installation costs and what grants may be available.
The Which? guide to boiler problems also has useful guidance on when repair makes financial sense versus replacement.
Whatever you decide, make sure your boiler receives an annual service — it’s the best way to catch expansion vessel deterioration and valve weeping before they become expensive emergencies. See our guide to boiler service costs to understand what you should be paying.
A Megaflo unvented cylinder stores hot water at mains pressure and suits large households with two or more bathrooms. A…
A magnetic boiler filter captures iron oxide sludge before it damages your pump and heat exchanger. Here is what they…
UK boiler efficiency ratings run from A+++ down to G. An old G-rated boiler wastes up to 30% of the…