Boiler Advice

“Boiler Efficiency Ratings Explained UK: A+++ to G and What They Mean for Your Bills”

October 26, 2026 • admin • 9 min read

Boiler Efficiency Ratings Explained UK: A+++ to G and What They Mean for Your Bills

If you are researching a new boiler or trying to work out whether your existing one is worth replacing, you will quickly encounter efficiency ratings: the ErP (Energy-related Products) letter scale from A+++ down to G, and the older SEDBUK percentage figure. Understanding what these ratings mean — and how they translate into real money on your gas bill — is essential for making a sensible decision. This guide explains the rating systems, shows you what they mean financially, and covers the UK regulations that make a high-efficiency boiler the only legal choice for replacement.

This article contains affiliate links. If you buy through them, we may earn a small commission at no extra cost to you. This doesn’t affect our editorial independence — we only recommend products we’d genuinely suggest to a friend.

EU ErP energy label on a Worcester Bosch Greenstar combi boiler showing A-rated efficiency
The ErP energy label now appears on all new boilers sold in the UK. A-rated boilers achieve 90%+ seasonal efficiency.

The ErP Rating System Explained

The Energy-related Products (ErP) Directive introduced a standardised energy label for heating products across Europe. Since 2015, all new boilers sold in the UK must carry this label, which rates heating efficiency on a scale from A+++ (most efficient) down to G (least efficient). The ratings are based on seasonal space heating efficiency — how efficiently the boiler converts gas to heat across a typical heating season, not just under ideal laboratory conditions.

In practice, all modern condensing combi and system boilers sold in the UK achieve at least an A rating. The A+ and above ratings are currently occupied by heat pumps and combined heat and power (CHP) systems, which can achieve seasonal efficiencies above 100% (because heat pumps extract heat from the environment rather than purely converting fuel). For a gas boiler, A is the realistic ceiling.

What Is SEDBUK?

SEDBUK stands for Seasonal Efficiency of Domestic Boilers in the UK. It is the percentage figure that underpins the ErP rating — the estimated annual efficiency of a boiler based on standardised seasonal conditions across a typical UK year. A SEDBUK of 90% means the boiler converts 90p of every £1 of gas into useful heat, with 10p lost up the flue.

The SEDBUK database was maintained by the Department for Energy Security and Net Zero (DESNZ) and is now incorporated into the Boiler Plus product list. You can check any boiler’s SEDBUK rating on the UK government’s Boiler Plus guidance page. When comparing boilers, the SEDBUK figure is more precise than the ErP letter — a boiler rated 89% and one rated 93% are both “A-rated” but with meaningfully different running costs.

Efficiency by Rating Band: What the Numbers Mean

ErP BandSeasonal EfficiencyTypical Boiler TypeStill Available New?
A+++125%+Heat pumps, CHP systemsYes (not gas boilers)
A++112–125%High-end heat pumpsYes (not gas boilers)
A+100–112%Heat pumpsYes (not gas boilers)
A90–100%Modern condensing gas boilerYes — all new gas boilers
B86–90%Older condensing boilerNot for new install
C / D82–86%Early condensing or non-condensingNo
E / F / GBelow 82%Pre-2005 non-condensing boilerNo — cannot be replaced like-for-like

Replacing a G-rated boiler (70% efficient) with a modern A-rated condensing boiler (92% efficient) in a typical UK semi-detached home could save £200–£400 per year on gas bills, according to the Energy Saving Trust.

Condensing vs Non-Condensing: Why It Matters

The key technological reason modern boilers are so much more efficient than older ones is condensing technology. A condensing boiler has a secondary heat exchanger that captures the heat from flue gases before they escape — heat that a non-condensing boiler simply vents away. The water vapour in the flue gases condenses back to liquid (hence the name), releasing its latent heat into the heating system.

This extra heat recovery is what pushes seasonal efficiency from around 75–78% (typical for a 1990s non-condensing boiler) to 90%+ for a modern condensing boiler. Non-condensing boilers were banned from new installations in England and Wales under the Part L Building Regulations (Conservation of Fuel and Power) in 2005, and in Scotland from 2007. If you are replacing any gas boiler today, it will be a condensing boiler — there is no other option.

How Much Can You Save by Replacing a G-Rated Boiler?

The financial saving from replacing a G-rated boiler depends on your home’s size, how much gas you use, and the specific efficiency improvement. The Energy Saving Trust publishes indicative savings figures based on a typical UK home:

Home TypeAnnual Gas Spend (est.)Old G-Rated Boiler WasteEstimated Annual Saving (A-rated replacement)
Small flat / 1-bed~£700~£168/yr~£130–£160/yr
Mid-terrace 3-bed~£1,100~£264/yr~£200–£260/yr
Semi-detached 4-bed~£1,500~£360/yr~£280–£360/yr
Large detached 5-bed~£2,200~£528/yr~£400–£520/yr

Savings vary depending on property size, insulation, tariff, and usage patterns. A new boiler typically costs £1,800–£3,500 installed — meaning payback periods of 5–12 years on energy savings alone, excluding the cost of emergency repairs you avoid on an ageing boiler. See our full boiler replacement cost guide for a detailed breakdown.

Old non-condensing gas boiler next to a modern condensing combi boiler showing size difference
A pre-2005 non-condensing boiler (left) vs a modern condensing combi. The efficiency difference — and the resulting energy saving — is substantial.

Part L Building Regulations and New Boiler Requirements

Under Part L of the UK Building Regulations (Approved Document L1B), any gas boiler installed in an existing UK dwelling must be a condensing boiler — and therefore A-rated — unless there is a genuine technical exemption (such as the flue route making a condensing installation impractical, which is rare). The regulations also require a room thermostat, TRVs on all radiators except one, and a time control — collectively known as Boiler Plus requirements.

Boiler Plus (introduced in 2018 for England) additionally requires at least one of the following to be fitted with a new boiler: flue gas heat recovery, smart thermostat with automation functions, weather compensation, or load compensation. In practice, most installers fit a smart thermostat to meet this requirement.

How to Find Your Boiler’s Efficiency Rating

If you want to check the efficiency of your current boiler, find the model name on the boiler’s data plate (usually inside the front panel or on a sticker on the casing), then search the SEDBUK database or check the boiler manufacturer’s website. Most major manufacturers — Worcester Bosch, Vaillant, Ideal, Baxi, Alpha — publish SEDBUK figures in their technical documentation. If your boiler’s SEDBUK is below 86%, replacement will almost certainly be cost-effective in the medium term.


Savings figures are estimates based on Energy Saving Trust methodology and typical UK energy prices as of October 2026. Actual savings vary. Always get a written quote before committing to a replacement.

#boiler-efficiency #condensing-boiler #energy-savings #erp-rating #sedbuk